LTW+ Zeroflame Plywood - Technical Specification

In the adverse event of a fire, Sonear LTW+ Zeroflame Retardant Plywood delays the spread of fire due to its chemically treated slow burning properties. The low flammability, low rate of burning and higher flame penetration time provides “Safety” and “Comfort.”

Testing Parameters IS: 5509 Requirement Sonear Infinity Results
Moisture Content 5% to 15% 7.8%
Treatment Core veneer to be soaked in 2% solution of Boric Acid solution of Borax for 40 Minutes (depending on veneer thickness) Satisfactory
Glue Shear Strength in Dry condition Individual Min. 1100 Newton
Average Min. 1350 Newton
1360 Newton
1590 Newton
Glue Shear Strength after Wet condition ndividual Min. 800 Newton
Average Min. 1000 Newton
1130 Newton
1280 Newton
Glue Shear Strength after Wet condition ndividual Min. 800 Newton
Average Min. 1000 Newton
1080 Newton
1140 Newton
Flammability Time taken for Second Ignition > 30 Minutes
(For 12mm Thick plywood)
44 Minutes
Flame Penetration Time for Flame Penetration to be > 30 Minutes
(For 12mm Thick plywood)
45 Minutes
Rate of Burning To be > 20 Minutes 36 Minutes